Clients: Crosslinx Transit Solutions – Constructors (Eglinton Crosstown); WSP, with EWC Designers (Ottawa Confederation Line Extension)
Location: Toronto and Ottawa, Ontario (other GPR work in Guelph and Sarnia)
Completed: 2019 to 2024
Services: GPR scanning, rebar location and cover measurement, covermeter surveys, coring, test cuts, sawn asphalt samples
On two light-rail projects, HAL used ground-penetrating radar (GPR) to find out exactly where the reinforcement is: once to help a construction team drill safely, and once to give a design team data that record drawings couldn't.
EGLINTON CROSSTOWN LRT, TORONTO (2020–2024)
For Crosslinx's trackwork team, HAL scanned the plinth locations on the East Don River Bridge and the Wynford bridge so the dowel holes anchoring the rail plinths could be drilled clear of the deck reinforcement, marking bar positions on the concrete without breaking out any concrete. HAL also located reinforcement along both faces of a 129 m wall at the East Portal, and cored and scanned beams and the centre platform slab at Mount Dennis Station. In 2024, HAL scanned two ramp slabs in the railway corridor at 216 Photography Drive to locate reinforcement and embedded glycol heating tubes.
CONFEDERATION LINE EXTENSION, OTTAWA (2019–2020)
For WSP and EWC Designers, HAL confirmed the reinforcement in five structures with no record drawings. On four pedestrian overpasses, GPR mapped the top-mat rebar and cores confirmed bar sizes. At Bilberry Creek Culvert (SN224510), where the new LRT crosses over the box culvert, HAL combined GPR, a covermeter survey, test cuts and full-depth cores to confirm bar size, spacing and cover.
OTHER GPR WORK (2021)
HAL uses the same GPR methods outside transit. In Guelph, HAL located the vertical and horizontal reinforcement in the masonry firewalls between townhouse blocks on Deerpath Drive, and in Sarnia HAL scanned the concrete in an existing building to map the embedded reinforcement.
WHY IT MATTERS
Without reliable rebar data, contractors risk cutting reinforcement and designers can't confirm capacity under new loads. In both cases, HAL's scans gave the team the measured information they needed to proceed.
NEED SIMILAR SCANNING OR TESTING?
HAL can scope it with you, from the site visit to the final report. Request a proposal